UV-Vis spectroscopy and the Beer-Lambert law
A coloured or UV-absorbing solution absorbs light most strongly at wavelengths matching electronic transitions in its molecules, and the Beer-Lambert law states that absorbance is directly proportional to both the absorbing species' concentration and the path length of light through the sample, turning a simple absorbance measurement into a direct quantitative determination of concentration.
Practise this conceptWhen light passes through a sample containing a substance that absorbs at the wavelengths used, some of that light is absorbed and the beam emerges weaker than it entered. UV-Vis spectroscopy measures this absorption as a function of wavelength, and because molecules absorb most strongly at wavelengths matching the energy gaps between their electronic states, the resulting absorption spectrum acts as a fingerprint that identifies the absorbing species and, quantitatively, how much of it is present.
The Beer-Lambert law puts this quantitative relationship on a precise footing: absorbance A (defined as the logarithm of the ratio of incident to transmitted light intensity) equals ε·c·l, where ε is the molar absorptivity (a constant specific to the absorbing species and the wavelength used), c is the concentration of the absorbing species, and l is the path length the light travels through the sample. Two proportionalities are packed into this single equation, and both matter for practical measurement. First, absorbance is directly proportional to concentration at fixed path length — this is the basis of essentially all quantitative UV-Vis analysis, since measuring the absorbance of a series of standard solutions with known concentrations and plotting absorbance against concentration produces a straight calibration line, from which an unknown sample's concentration can be read directly once its absorbance is measured. Second, absorbance is directly proportional to path length at fixed concentration, which is why the cuvettes used to hold samples in a spectrophotometer have a precisely fixed, known path length (very commonly 1 cm), so that path length can be treated as a constant and concentration extracted cleanly from a single absorbance reading.
The Beer-Lambert law holds well at low to moderate concentrations, but real measurements deviate from strict linearity at high concentration — closely packed absorbing molecules begin to interact with each other, and instrumental effects such as stray light become proportionally more significant, both of which curve the absorbance-concentration relationship away from the ideal straight line. Reliable quantitative analysis therefore requires keeping sample concentrations within the range where the law's linear approximation genuinely holds, typically verified by confirming the calibration curve remains straight across the concentrations of interest.
Key ideas
Requires: The mole and amount of substance
Common misconceptions
- Absorbance in UV-Vis spectroscopy depends only on the sample's concentration, not on the path length of light through it.
- The Beer-Lambert law holds exactly at any concentration, with no upper limit where deviations appear.
- A substance absorbs light equally at every wavelength, with no dependence on its particular electronic structure.